Allison Transmission Oil Coolers . . .

Brazed

ALLISON WORLD TRANSMISSION : SHELL AND TUBE OIL COOLERS
Allison
WT
Model
Series
Typical
WT Application
Does Transm. Have Retarder Provision Typical Engine Input Hp Min. Oil Flow
Rate GPM Converter/ Retarder

Maximum
Intermittent
Oil Temp.
Converter/ Retarder

Min.
Water Flow Rate GPM
Model
No 3-1277D
1 pass
on water side
BTU/min

Model
No 3-1249T
1 pass
on
water
side BTU/min

Model No     3-1259B
1 pass
on
water
side BTU/min
Model
No. 3-1270A 
2 pass
on
water side BTU/min
Model
No. 3-1279B
(5 Baffles) 1 pass on
water side BTU/min
Model
No. 3-1279C (7 Baffles)
1 pass on
water side BTU/min
Model
No. 3-1274B
2 pass
on
water
side
BTU/min
MD3000 On Highway No 275 12 300°F 50 3,100 3,130
MD3000R On Highway Yes 275 12 / 60 300°F / 330°F 50 3,170 / 12,000 3,300 / 13,000
B300 Bus No 275 12 300°F 50 3,100 3,130  
B300R Bus Yes 275 12 / 60 300°F / 330°F 50 3,170 / 12,000 3,300 / 13,000
B400 Bus No 295 12 300°F 50 3,100 3,130  
B400R Bus Yes 295 12 / 60 300°F / 330°F 50 3,170 / 12,000 3,300 / 13,000 3,130 / 13,270 3,400 / 13,840 3,450 / 13,353
HD4000 On Highway No 450 17 300°F 60 4,040
HD4000R On Highway Yes 450 17 / 60 300°F / 330°F 60   4,080 / 13,800 4,400 / 14,500 4,550 / 13,800
B500 Bus No 450 17 300°F 60 4,040  
B500R Bus Yes 450 17 / 60 300°F / 330°F 60   4,080 / 13,800 4,400 / 14,500 4,550 / 13,800

ALLISON WORLD TRANSMISSION : SHELL AND TUBE OIL COOLERS
Allison
Transmission
Model
Series
Typical
WT Application
Does
Transm.
Have
Retarder
Provision
Typical
Engine
Input Hp
Min. Oil Flow Rate GPM Converter/ Retarder Maximum Intermittent
Oil Temp.
Converter/
Retarder
Min.
Water
Flow
Rate
GPM
Model
No. 3-1178A
1 pass
on
water
side BTU/min
Model
No. 3-1105A
1 pass
on
water
side BTU/min
Model
No. 3-1255A
2 pass
on
water
side BTU/min
Model
No. 3-1234A
1 pass
on
water
side BTU/min
Model
No. 3-1127A
1 pass
on
water
side BTU/min

Model
No. 3-1192A
2 pass
on
water side BTU/min

Model
No. 3-1179B
1 pass
on
water
side
BTU/min
AT540 / AT 1540 On Highway No 175 4.5 300°F 50 1,230 1,450 1,310
MT600
300 CONVERTER
On Highway No 250 8 300°F 75 2,020 2,280 2,120
MTB600
300 CONVERTER
On Highway Yes 250 8 / 60 300°F / 330°F 75 2,050 / 10,800 2,200 / 11,300 2,600 / 14,200
MT600
400 CONVERTER
On / Off Highway No 300 12 300°F 90 2,820 3,100 2,940
MTB600
400 CONVERTER
On / Off Highway Yes 300 12 / 60 300°F / 330°F 90 3,000 / 11,400 3,000 / 11,700 3,700 / 14,600
HT700 On Highway Yes 425 15 300°F 125 3,550 3,450 4,500
HT700
With
3 Gear
Pump
On Highway No 425 22 300°F 125 4,500 5,000 4,650
HT700
With
Input Retarder
On Highway Yes 425 15 / 60 300°F / 330°F 125 3,550 / 12,200 3,450 / 13,270 4,500 / 15,800
HTB700 On Highway Yes 425 15 / 60 300°F / 330°F 125 3,550 / 12,200 3,450 / 13,270 4,500 / 15,800
CLT700 Off Highway No 300 to 500 15 275°F 125 2,750 2,600 3,350
CLBT700 Off Highway Yes 300 to 500 22 / 70 275°F / 330°F 125 4,500 / 17,500
CLT 5000 / 6000 Off Highway No 400 to 700 35 275°F 125 5,350 5,025 4,500 / 17,500
CLBT 5000 / 600 Off Highway Yes 400 to 700 35 / 110 275°F / 330°F 125 4,500 / 17,500