Allison
Transmission Oil Coolers
. . .
Brazed
|
| ALLISON
WORLD TRANSMISSION : SHELL AND TUBE OIL COOLERS |
Allison
WT
Model
Series |
Typical
WT Application |
Does
Transm. Have Retarder Provision |
Typical
Engine Input Hp |
Min.
Oil Flow
Rate GPM Converter/ Retarder |
Maximum
Intermittent
Oil Temp.
Converter/ Retarder
|
Min.
Water Flow Rate GPM |
Model
No 3-1277D
1 pass
on water side
BTU/min |
Model
No 3-1249T
1 pass
on
water
side
BTU/min
|
Model
No 3-1259B
1 pass
on
water
side BTU/min |
Model
No. 3-1270A
2 pass
on
water side BTU/min |
Model
No. 3-1279B
(5 Baffles) 1 pass on
water side BTU/min |
Model
No. 3-1279C (7 Baffles)
1 pass on
water side BTU/min |
Model
No. 3-1274B
2 pass
on
water
side
BTU/min |
| MD3000 |
On
Highway |
No |
275 |
12 |
300°F |
50 |
3,100 |
3,130 |
|
|
|
|
|
| MD3000R |
On
Highway |
Yes |
275 |
12
/ 60 |
300°F
/ 330°F |
50 |
|
|
3,170
/ 12,000 |
3,300
/ 13,000 |
|
|
|
| B300 |
Bus |
No |
275 |
12 |
300°F |
50 |
3,100 |
3,130 |
|
|
|
|
|
| B300R |
Bus
|
Yes |
275 |
12
/ 60 |
300°F
/ 330°F |
50 |
|
|
3,170
/ 12,000 |
3,300
/ 13,000 |
|
|
|
| B400 |
Bus |
No |
295 |
12 |
300°F |
50 |
3,100 |
3,130 |
|
|
|
|
|
| B400R |
Bus
|
Yes |
295 |
12
/ 60 |
300°F
/ 330°F |
50 |
|
|
3,170
/ 12,000 |
3,300
/ 13,000 |
3,130
/ 13,270 |
3,400
/ 13,840 |
3,450
/ 13,353 |
| HD4000 |
On
Highway |
No |
450 |
17 |
300°F |
60 |
|
4,040
|
|
|
|
|
|
| HD4000R |
On
Highway |
Yes |
450 |
17
/ 60 |
300°F
/ 330°F |
60 |
|
|
|
|
4,080
/ 13,800 |
4,400
/ 14,500 |
4,550
/ 13,800 |
| B500 |
Bus |
No |
450 |
17 |
300°F |
60 |
|
4,040 |
|
|
|
|
|
| B500R |
Bus |
Yes |
450 |
17
/ 60 |
300°F
/ 330°F |
60 |
|
|
|
|
4,080
/ 13,800 |
4,400
/ 14,500 |
4,550
/ 13,800 |
| ALLISON
WORLD TRANSMISSION : SHELL AND TUBE OIL COOLERS |
Allison
Transmission
Model
Series |
Typical
WT Application |
Does
Transm.
Have
Retarder
Provision |
Typical
Engine
Input Hp |
Min.
Oil Flow Rate GPM Converter/ Retarder |
Maximum
Intermittent
Oil Temp.
Converter/
Retarder |
Min.
Water
Flow
Rate
GPM |
Model
No. 3-1178A
1 pass
on
water
side BTU/min |
Model
No. 3-1105A
1 pass
on
water
side BTU/min |
Model
No. 3-1255A
2 pass
on
water
side BTU/min |
Model
No. 3-1234A
1 pass
on
water
side BTU/min |
Model
No. 3-1127A
1 pass
on
water
side BTU/min |
Model
No. 3-1192A
2 pass
on
water side BTU/min
|
Model
No. 3-1179B
1 pass
on
water
side
BTU/min |
| AT540
/ AT 1540 |
On
Highway |
No |
175 |
4.5 |
300°F |
50 |
1,230 |
1,450 |
1,310 |
|
|
|
|
MT600
300 CONVERTER |
On
Highway |
No |
250 |
8 |
300°F |
75 |
2,020 |
2,280 |
2,120 |
|
|
|
|
MTB600
300 CONVERTER |
On
Highway |
Yes |
250 |
8
/ 60 |
300°F
/ 330°F |
75 |
|
|
|
|
2,050
/ 10,800 |
2,200
/ 11,300 |
2,600
/ 14,200 |
MT600
400 CONVERTER |
On
/ Off Highway |
No |
300 |
12 |
300°F |
90 |
2,820 |
3,100 |
2,940 |
|
|
|
|
MTB600
400 CONVERTER |
On
/ Off Highway |
Yes |
300 |
12
/ 60 |
300°F
/ 330°F |
90 |
|
|
|
|
3,000
/ 11,400 |
3,000
/ 11,700 |
3,700
/ 14,600 |
| HT700 |
On
Highway |
Yes |
425 |
15 |
300°F |
125 |
|
|
|
|
3,550 |
3,450 |
4,500 |
HT700
With
3 Gear
Pump |
On
Highway |
No |
425 |
22 |
300°F |
125 |
|
|
|
4,500 |
5,000 |
4,650 |
|
HT700
With
Input Retarder |
On
Highway |
Yes |
425 |
15
/ 60 |
300°F
/ 330°F |
125 |
|
|
|
|
3,550
/ 12,200 |
3,450
/ 13,270 |
4,500
/ 15,800 |
| HTB700 |
On
Highway |
Yes |
425 |
15
/ 60 |
300°F
/ 330°F |
125 |
|
|
|
|
3,550
/ 12,200 |
3,450
/ 13,270 |
4,500
/ 15,800 |
| CLT700 |
Off
Highway |
No |
300
to 500 |
15 |
275°F |
125 |
|
|
|
|
2,750 |
2,600 |
3,350 |
| CLBT700 |
Off
Highway |
Yes |
300
to 500 |
22
/ 70 |
275°F
/ 330°F |
125 |
|
|
|
|
|
|
4,500
/ 17,500 |
| CLT
5000 / 6000 |
Off
Highway |
No |
400
to 700 |
35 |
275°F |
125 |
|
|
|
|
5,350
|
5,025 |
4,500
/ 17,500 |
| CLBT
5000 / 600 |
Off
Highway |
Yes |
400
to 700 |
35
/ 110 |
275°F
/ 330°F |
125 |
|
|
|
|
|
|
4,500
/ 17,500 |
< Floating
Bundle